Vertiv Liebert Ita2 10 Kva (Three Phase To Single Phase / Single Phase To Single Phase Online UPS.
Featuring true online double conversion technology, unity power factor and an extremely compact rack-tower design, Liebert ITA2 is the perfect power protection solution for your computer rooms, storage and network equipment.
Description With a unity output power factor, Liebert ITA2 perfectly matches the needs of modern IT loads, and with its wide input voltage and frequency range it effectively reduces the need for battery intervention, thus prolonging battery life. It is also endowed with intelligent fans with automatic speed control, which effectively save energy and reduce noise. Liebert ITA2 supports common battery configurations between paralleled UPS and the number of batteries per string, which can be arranged flexibly, facilitating the utilization of different battery systems and saving on battery investment. An extra powerful battery charger across all models capable of recharging high capacity battery strings ensures a fast charge-restoration even after a prolonged power outages. Liebert ITA2 offers enhanced flexibility with a wide range of accessories for both stand-alone and rack-mount installations. When rack mounted, it allows to install up to 40 kVA UPS in just 3 U of space, achieving a remarkable space saving. Parallelability and maintenance are facilitated through the use of dedicated maintenance bypass option while extended backup time can be provided with matching battery modules (10-20 kVA) for a neat rack-mounted installation. Liebert ITA2 features a multi-lingual LCD user interface allowing close control and monitoring of system status and performance.
Technical Specifications
Ratings (kVA) 10 15 20 30 40
Input
Nominal input voltage (V) 380/400/415 (three-phase + neutral) 380/400/415 (Line voltage)
Input voltage range without
battery discharge (V) 173 to 498*
176 ~ 288, at full load
100Vac ~ 176Vac, linear derating
100Vac, at half load
Nominal input frequency (Hz) 50/60
Input frequency range (Hz) 40 ~ 70
Bypass voltage tolerance (%) selectable from +20 to -40
Upper limit: +10%, +15% or +20%;
default: +20%; Lower limit: -10%, -20%,
-30% or -40%; default: -40%
Bypass frequency tolerance (%) ±20 (±10 selectable) ±5Hz, ±10Hz
Input power factor at full load (kW/kVA) 0.99 ≥0.99, at full load; ≥0.98, at half load
Current THD at full linear load (THDI%) ≤3* <3% (for linear full load)
Battery Management
Battery blocks per string 24-40* 32-40 32-40**
Voltage temperature compensation
(mV/°C/Cell) -3 default 3 mV/cell/, can be set 0~5mV/
cell/ from Paramset
Battery charger max. current (A) 13 ≤ 13A
Output
Nominal output voltage (V) 380/400/415 (three-phase) or 220/230/240 (single-phase) 380/400/415 (three-phase)
Nominal output frequency (Hz) 50/60
Maximum active power (kW) 10 15 20 30 40
THDv at full linear load (%) ≤2 < 2% (linear load);
< 5% (non-linear load)
Inverter overload capacity at 25°C
105% for 60 min
125% 5 min
150% for 1 min
> 150%, 200 ms
105% for 60 min
125% 10 min
150% for 1 min
> 150%, 200 ms
Up to 105% continuous
105%-125% for 10 min
125%-150% for 1 min
> 150%, 200 ms
Efficiency
Double conversion efficiency Up to 96.2% 96.6%
ECO Mode Efficiency Up to 99% 99%
Dimensions and Weight
Dimensions (W x D x H) (mm)
430 x 500 x 130 (UPS)
430 x 500 x 130 (Battery module 3U, 16 x 9 Ah)
430 x 650 x 85 (Battery module 2U, 16 x 9 Ah)
430 x 500 x 175 (single POD),
430 x 500 x 260 (1+1 parallel POD)
430 x 500 x 130 (UPS)
430x500x175 (single POD)
430 x 500 x 260
(1+1 parallel POD)
430 x 590 x 130 (3U) ***
430 x 730 x 173 (4U) (single POD)
430 x 730 x 261 (6U)
(1+1 parallel POD)
Net Weight (kg)
23 (UPS)
51 (Battery module 3U, 16 x 9 Ah)
51 (Battery module 2U, 16 x 9 Ah)
18 (single POD), 30 (1+1 parallel POD)
23 (UPS)
18 (single POD)
30 (1+1 parallel POD)
30/52 (UPS)
20/30 (Single POD)
28/43 (1+1 Parallel POD)
General
Noise at 1 m (dBA) ≤58 <60 63
Ventilation Front to back
Maximum altitude 1500 m without derating (max. 3000 m)
Protection level IEC (60529) IP20
General and safety requirements for UPS EN/IEC/AS/BS 62040-4
EMC requirements for UPS EN/IEC/AS/BS 62040-2
UPS classification according to
CEI EN 62040-3 VFI-SS-111
Enviromental aspects EN/IEC/BS 62040-4
Brand: | EMERSON / VERTIV |
---|---|
Model number: | EMERSON / VERTIV LIEBERT ITA2 10 KVA Online UPS |
Part Number: | EMERSON / VERTIV LIEBERT ITA2 10 KVA Online UPS |
Seller SKU: | EMERSON / VERTIV LIEBERT ITA2 10 KVA Online UPS |
Origin: | United States |
Availability: | In Stock |
Minimum order quantity: | 1 |
Date first listed on Authorized Software Reseller : | May 27, 2024 |
Vertiv Liebert Ita2 10 Kva (Three Phase To Single Phase / Single Phase To Single Phase Online UPS.
Featuring true online double conversion technology, unity power factor and an extremely compact rack-tower design, Liebert ITA2 is the perfect power protection solution for your computer rooms, storage and network equipment.
Description With a unity output power factor, Liebert ITA2 perfectly matches the needs of modern IT loads, and with its wide input voltage and frequency range it effectively reduces the need for battery intervention, thus prolonging battery life. It is also endowed with intelligent fans with automatic speed control, which effectively save energy and reduce noise. Liebert ITA2 supports common battery configurations between paralleled UPS and the number of batteries per string, which can be arranged flexibly, facilitating the utilization of different battery systems and saving on battery investment. An extra powerful battery charger across all models capable of recharging high capacity battery strings ensures a fast charge-restoration even after a prolonged power outages. Liebert ITA2 offers enhanced flexibility with a wide range of accessories for both stand-alone and rack-mount installations. When rack mounted, it allows to install up to 40 kVA UPS in just 3 U of space, achieving a remarkable space saving. Parallelability and maintenance are facilitated through the use of dedicated maintenance bypass option while extended backup time can be provided with matching battery modules (10-20 kVA) for a neat rack-mounted installation. Liebert ITA2 features a multi-lingual LCD user interface allowing close control and monitoring of system status and performance.
Technical Specifications Ratings (kVA) 10 15 20 30 40 Input Nominal input voltage (V) 380/400/415 (three-phase + neutral) 380/400/415 (Line voltage) Input voltage range without battery discharge (V) 173 to 498* 176 ~ 288, at full load 100Vac ~ 176Vac, linear derating 100Vac, at half load Nominal input frequency (Hz) 50/60 Input frequency range (Hz) 40 ~ 70 Bypass voltage tolerance (%) selectable from +20 to -40 Upper limit: +10%, +15% or +20%; default: +20%; Lower limit: -10%, -20%, -30% or -40%; default: -40% Bypass frequency tolerance (%) ±20 (±10 selectable) ±5Hz, ±10Hz Input power factor at full load (kW/kVA) 0.99 ≥0.99, at full load; ≥0.98, at half load Current THD at full linear load (THDI%) ≤3* <3% (for linear full load) Battery Management Battery blocks per string 24-40* 32-40 32-40** Voltage temperature compensation (mV/°C/Cell) -3 default 3 mV/cell/, can be set 0~5mV/ cell/ from Paramset Battery charger max. current (A) 13 ≤ 13A Output Nominal output voltage (V) 380/400/415 (three-phase) or 220/230/240 (single-phase) 380/400/415 (three-phase) Nominal output frequency (Hz) 50/60 Maximum active power (kW) 10 15 20 30 40 THDv at full linear load (%) ≤2 < 2% (linear load); < 5% (non-linear load) Inverter overload capacity at 25°C 105% for 60 min 125% 5 min 150% for 1 min > 150%, 200 ms 105% for 60 min 125% 10 min 150% for 1 min > 150%, 200 ms Up to 105% continuous 105%-125% for 10 min 125%-150% for 1 min > 150%, 200 ms Efficiency Double conversion efficiency Up to 96.2% 96.6% ECO Mode Efficiency Up to 99% 99% Dimensions and Weight Dimensions (W x D x H) (mm) 430 x 500 x 130 (UPS) 430 x 500 x 130 (Battery module 3U, 16 x 9 Ah) 430 x 650 x 85 (Battery module 2U, 16 x 9 Ah) 430 x 500 x 175 (single POD), 430 x 500 x 260 (1+1 parallel POD) 430 x 500 x 130 (UPS) 430x500x175 (single POD) 430 x 500 x 260 (1+1 parallel POD) 430 x 590 x 130 (3U) *** 430 x 730 x 173 (4U) (single POD) 430 x 730 x 261 (6U) (1+1 parallel POD) Net Weight (kg) 23 (UPS) 51 (Battery module 3U, 16 x 9 Ah) 51 (Battery module 2U, 16 x 9 Ah) 18 (single POD), 30 (1+1 parallel POD) 23 (UPS) 18 (single POD) 30 (1+1 parallel POD) 30/52 (UPS) 20/30 (Single POD) 28/43 (1+1 Parallel POD) General Noise at 1 m (dBA) ≤58 <60 63 Ventilation Front to back Maximum altitude 1500 m without derating (max. 3000 m) Protection level IEC (60529) IP20 General and safety requirements for UPS EN/IEC/AS/BS 62040-4 EMC requirements for UPS EN/IEC/AS/BS 62040-2 UPS classification according to CEI EN 62040-3 VFI-SS-111 Enviromental aspects EN/IEC/BS 62040-4
No reviews
Complete this Enquiry Form to obtain additional information about our services or send personal complaints. We will analyze your enquiry and return to you shortly by email or phone.